Over the past decade, EMCCD (Electron Multiplying Charge Coupled Device) cameras have revolutionized the world of life science imaging. Because they boost signal-to-noise ratio by multiplying incoming light signals, EMCCD cameras have given researchers access to the entire gamut of low-light imaging applications—from whole animal in vivo imaging to super-resolution fluorescence visualization of sub-cellular structures—allowing researchers to see biological entities that were difficult to see before.

But there’s a problem: EMCCD, as well as CCD cameras report imaging data in Analog-to-Digital Units (ADUs), which are arbitrary. These ADUs (called “grey scale units” in Europe) are completely dependent on the camera’s gain settings, which vary between manufacturers and even camera to camera. In most cases, manufacturers do not measure or reveal these gain values at each setting.

Because the measurement unit in scientific cameras is not standardized, researchers cannot reliably compare imaging data or reproduce their results between, or even within their own labs.

 
Fibroblast cell triple-stained 
Fibroblast cell triple-stained with DAPI, FITC-Actin and Mito-Tracker. The image was taken with the Evolve camera and Olympus DSU confocal. (Source: Graham Dellaire, PhD, Nuclear Structure and Cancer Laboratory, Dalhousie University, Halifax, Nova Scotia)

Imagine a world where researchers could reproduce their imaging experiments and more directly compare their data. Think of the scientific advances we could make if studies were more quantitative and verifiable, and consider the new insights we could derive from being able to integrate data from different experiments.

Recent advances in EMCCD technology have solved the measurement problem by using the photoelectron—an absolute unit—to standardize imaging experiments. This innovation is helping to standardize imaging experiments and advance emerging fields such as super-resolution microscopy.

Standardizing Imaging Results
EMCCDs work by generating a greater signal than was initially emitted by the incoming signal itself, thus producing sufficient multiplication to detect even a single fluorophore.

As with CCD cameras, incoming photons generate photoelectrons, which are then shifted through pixels and each pixel is measured sequentially as it is read out. In an EMCCD, however, incoming photons are sequentially moved into an extended register where high voltages are applied, and the electron undergoes impact ionization, multiplying one electron into many.

Until recently, EMCCD cameras counted photoelectrons by converting them into ADUs. This value, however, depends entirely on the gain settings of the camera, and because these settings are undefined by most camera manufacturers and easily manipulated by users, ADUs are not a reliable way in which to evaluate imaging experiments between cameras or between labs. For example, if imaged at different gain settings, a feature with a given quantum yield will appear to have different brightness levels and possess different ADU values. This lack of reproducibility confines the significance of the data to a single snapshot in time, limiting its contribution to future scientific discovery.

 
  The Evolve EMCCD Camera  
click to enlarge 
 
The Evolve EMCCD camera allows the user to manually input EM Gain settings. While the ADU count rises significantly between 400× and 800× EM Gain, the
electron count does not increase, giving the researcher an absolute measurement in real time.

Absolute Units
The only way to achieve reproducible, quantitative imaging data is to measure that data in absolute units—in this case, the photoelectron.

If a camera’s gain settings are available, researchers can manually back-calculate from ADUs to photoelectrons—a long, complicated, and painstaking process that requires careful characterization of the camera. Few biologists take the time or have the know-how to make these calculations.

The Evolve camera’s Quant-View feature uses the camera’s gain settings to automatically back-calculate pixel values to the number of photoelectrons, presenting brightness level in terms of photoelectrons in real time. By standardizing the unit of measurement, Quant-View technology allows researchers to compare images taken at different gain settings in absolute terms.

According to Sidney L. Shaw, Assistant Professor, Department of Physics, Indiana University, “The Evolve camera finally gets rid of arbitrary gray levels in favor of photoelectron counts, a meaningful standard that scientists can use for comparing their imaging systems and their image-based data.”

Aging Instability
As EMCCD chips age, their gain amplification characteristics change and EM gain output is reduced. Thus, a camera that had a 100× EM gain may not have the same gain in a matter of weeks, which will affect the accuracy and reproducibility of imaging data.

Knowing the camera’s gain settings is critical to any truly quantitative application. Because of EMCCD chip deterioration, it is crucial to re-calibrate the camera at regular intervals. In the context of EMCCD cameras, this involves calibrating the gain so that a given brightness on the image corresponds to a reliable measurement of the “real-world” value representing the number of photons that a pixel has registered.

Previous cameras would ‘calibrate’ by altering electronic gain settings to closely match what the user requested. The Evolve camera takes the calibration one step further—it measures the real gain setting applied by the camera and uses the real number to back calculate the image data to the photoelectron number. For example, if a user dials in 100× EM gain, the calibration routine will ‘tweak’ the camera’s electronic settings and may actually only provide 99.2×. While other cameras settle for the “as close as possible” approach, the Evolve camera features Rapid-Cal, which measures the real gain being applied and corrects the data in real time, and uses this calibration to accurately quantify data in photoelectrons.

Benefits of EMCCD for Super-Resolution Microscopy
Until recently, all fluorescence microscopy methods had been limited in resolution by the diffraction limit for the wavelength of light. This meant nothing below a quarter of a micrometer could be resolved, yet many cellular substructures are much smaller.

Now, new “super-resolution fluorescence microscopy” techniques have broken this barrier, allowing researchers to see structures only tens of nanometers apart. These technologies benefit from advances in EMCCD technology to record and quantify imaging experiments.

Fluorescence Photoactivation Localization Microscopy (FPALM) leverages the unique properties of photoactivatable chromophores, fluorescent labels that can be genetically encoded. In FPALM, structures of interest are labeled using photoswitchable fluorophores that can be activated by a flash of light at a particular wavelength. The molecule then emits a photon at a different but specific wavelength one nanosecond later, which an EMCCD camera records.

The activation process produces a distribution of well-separated “switched on” molecules, the centroids of which are triangulated from the photon distribution. After the initial round of molecules photobleach, another flash of light at the proper wavelength activates another round of molecules for imaging. This process is repeated until the user assembles an image of the structure of interest with very high structural resolution.

Spurious noise events, characterized by the appearance of a single bright pixel, are a phenomenon common to EMCCD cameras. Because FPALM looks at single molecules, spurious noise events can complicate FPALM imaging. The Evolve uses an on-the-fly noise reduction algorithm (Background Event Reduction Technology, or BERT) that can be applied to significantly reduce spurious events, which are generated by dark current or the CCD voltage clocks.

Because the Evolve converts incoming light signals into a photoelectron count in real time, the mean number of photoelectrons contributing to a given pixel can be presented on the fly without arduous secondary calibrations and calculations. This absolute unit brightness calculation leads to more meaningful comparisons, thus enhancing the accuracy of FPALM research.

Summary
Current advances in EMCCD technology have replaced an arbitrary unit of measurement—the ADU—with the photoelectron in an effort to standardize imaging data and make imaging experiments reproducible between scientists.

Because it enables accurate and reproducible quantitation of images in absolute units, and because of the quantitative calibration feature, the Evolve EMCCD can be leveraged towards advances in super-resolution microscopy.

This article was published in Bioscience Technology magazine: Vol. 32, No. 10, October, 2008, pp. 24-26.

Join the Discussion
Rate Article:  Average 4 out of 5
register or log in to comment on this article!

0 Comments

Add Comment

Text Only 2000 character limit

Page 1 of 1

Research Exchange

Microplate Reader Test Plates Ensure Reliable Microplate Reader Operation

Aug 20

Use of a certified test plate can help to increase efficiency when calibrating microplate readers.

Automated Imaging Assisted Cell Line Development

Aug 19

Improve titer, quality and speed in cell line development.

New Frontiers: The Changing World of Biospecimen Collection and Management

Jul 30

The growth of biomarker research and personalized medicine requires more unified and large-scale software systems to track biological materials.

Optical Imaging in Stem Cell Research

Jun 1

Developing sensitive, non-invasive technologies to monitor engraftment in vivo is essential to accelerate the clinical implementation of cell therapies.

Step up to the MIQE

Mar 30

Over the years, polymerase chain reaction (PCR) has evolved into a readily automated, high throughput quantitative technology. Real-time quantitative PCR (qPCR) has become the industry standard for the detection and quantification of nucleic acids for multiple application, including quantification of RNA levels. But a lack of consensus among researchers on how to best perform and interpret qPCR experiments presents a major hurdle for advancement of the technology. This problem is exacerbated by insufficient experimental detail in published work, which impedes the ability of others to accurately evaluate or replicate reported results.

Fast Optimization of a Multiplex Influenza Identification Panel Using a Thermal Gradient

Mar 30

The year 2009 was marked by the emergence of a novel influenza A (H1N1) virus that infects humans. There is a need to identify the different strains of influenza virus for purposes of monitoring the H1N1 strain pandemic and for other epidemiological and scientific purposes.

Advantages of Monolithic Laser Combiner Technology in Confocal Microscopy Systems

Jan 6

Fluorescence microscopy techniques require a reliable light source at the desired wavelength or wavelengths, with minimal downtime for maintenance and alignment. Lasers are a popular light source, although the alignment and upkeep of laser combiners is a time-consuming prospect for many users.

Size-Exclusion Chromatography for Purification of Biomolecules

Dec 2 2009

Size-exclusion chromatography (SEC) is a popular method to separate biomolecules based on their size. Primarily, it is applied to the separation of biopolymers such as proteins and nucleic acids, i.e. water-soluble polymers.

Using the Tecan Genesis Workstation to Automate a Cytometric Bead Array (CBA) Immunoassay

Mar 11

The poster describe the process involved in automating a Cytometric Bead Array (CBA) immunoassay developed to measure relative concentrations of serum antibodies against Tetanus (TT), Sperm Whale Myoglobin (SWM) and Keyhole Limpet Hemocyanin (KLH) in KLH-immunized volunteers.

Ensuring Quality in Assays Performed with Automated Liquid Handlers

Feb 2

The focus of this presentation is to highlight the need of ensuring quality in important assays performed with automated liquid handlers. Nearly all assays performed within a laboratory are volume-dependent. In turn, all concentrations of biological and chemical components in these assays, as well as the associated dilution protocols, are volume-dependent. Because analyte concentration is volume-dependent, an assay’s results might be falsely interpreted if liquid handler variability and inaccuracies are unknown or if the system(s) go unchecked for a long period.

Inkjet System for Protein Crystallography

Feb 1

X-ray crystallography is used routinely by scientists to obtain the three dimensional structure of a biological molecule of interest.Such information can be used to determine how a pharmaceutical interacts with a protein target and what changes might improve functionality. However, the crystallization of macromolecules still remains a serious hindrance in structural determination despite impressive advances in screening methods and technologies.

Attention Deficit & Hyperactivity in a Drosophila Memory Mutant

Attention Deficit & Hyperactivity in a Drosophila Memory Mutant

Nov 9 2009

Action selection is modulated by external stimuli either directly or via memory retrieval. In a constantly changing environment, animals have evolved attention-like processes to effectively filter the incoming sensory stream. These attention-like processes, in turn, are modulated by memory. The neurobiological nature of how attention, action selection and memory are inter-connected is unknown. We describe here new phenotypes of the memory mutant radish in the fruit fly Drosophila.

Efficient Bayesian approach for multilocus association mapping including gene-gene interactions.

1 hour ago

ABSTRACT: BACKGROUND: Since the introduction of large-scale genotyping methods that can be utilized in genome-wide association (GWA) studies for deciphering complex diseases, statistical genetics has been posed with a tremendous challenge of how to most...

Influenza A/pandemic 2009/H1N1 in the setting of allogeneic hematopoietic cell transplantation: a potentially catastrophic problem in a vulnerable population.

2 hours ago

We describe Influenza A/pandemic 2009/H1N1 in two allogeneic hematopoietic cell transplantation recipients. The main presentation in both cases consisted of flu-like symptoms manifesting as, fever, arthralgias and myalgias. The virus was isolated in one case...

Outcomes of matched sibling and alternative donor stem cell transplantation for 26 children with severe aplastic anemia.

2 hours ago

In this study, we reported the outcomes of hematopoietic stem cell transplantation (HSCT) as a treatment modality for pediatric patients admitted over the past 20 years in a single institute. From January 1989 to January 2007, 26 patients with a median age of 8...

Structural Interpretation in Composite Systems Using Powder X-ray Diffraction: Applications of Error Propagation to the Pair Distribution Function.

2 hours ago

PURPOSE: To develop a method for drawing statistical inferences from differences between multiple experimental pair distribution function (PDF) transforms of powder X-ray diffraction (PXRD) data. METHODS: The appropriate treatment of initial PXRD error estimates...

Prokariotic Cell Collection in Denmark

Nov 6 2009

I would like to know about a prokariotic cell collection in Denmark. Is there a cell bank in this country? I need a Lactobacillus strain for a fermentation assay and this information about the bank is very helpful for me.

Request for Entries

Oct 16 2009

Ask the Experts is your chance to get the answers to questions on applications, materials, methods, processes, and technologies. Email you question to bst_web@advantagemedia.com, and the editors of Bioscience Technology will find an appropriate expert to answer it. Watch this space in the future to see the questions your colleagues are posting.          

STAY INFORMED: SUBSCRIBE TO

Magazine and E-mail Newsletters

Loading...
E-mail:   

MULTIMEDIA

Video:

Viewing SureFocus Slides

Jun 11

A demonstration of SureFocus Microscope Slides in the review of AFB Smears. SureFocus Slides are a patent-pending breakthrough in tuberculosis detection, as their fluorescent staining circle remains visible during review, Fluorescence Microscopy.

Podcasts:

Allen Institute for Brain Research

Allen Institute for Brain Research

Oct 14 2009

Discussed in this interview are both the mouse brain project and the human cortex project with an emphasis on the importance of these projects to neuroscience research.